Sign In | Join Free | My himfr.com
Home > Blue Green Algae Sensor >

DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor

    Buy cheap DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor from wholesalers
     
    Buy cheap DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor from wholesalers
    • Buy cheap DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor from wholesalers
    • Buy cheap DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor from wholesalers

    DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor

    Ask Lasest Price
    Brand Name : Desun Uniwill
    Model Number : DS305
    Price : According to the specific quantity
    Payment Terms : T/T, L/C, D/A, D/P
    Delivery Time : 7-15 working days
    • Product Details
    • Company Profile

    DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor

    DS206Fluorescent blue-green algae sensor for water quality monitoring in rivers and lakes RS485, MODBUS protocol

    Introduction

    The online blue-green algae sensor uses the principle of fluorescence method, which is more efficient and faster than the traditional manua counting method, and can be monitored in real time online. The senso has better repeatability and stability. With automatic cleaning brush, it can eliminate air bubbles and reduce the impact of contamination on the measurement, make the maintenance cycle longer, and maintain excellen stability for long-term online use It can play an early warning role on algae reproduction.

    Features

    ★ Digital sensor, RS-485 output, support MODBUS

    ★ With automatic cleaning brush to prevent contamination and eliminate air bubbles

    ★ Direct measurement, simpler than traditional manual counting method

    ★ Continuous online monitoring, real-time control of water quality dynamics


    Technical parameter

    Product nameBlue-green Algae Sensor
    modelDS206
    principleFluorescence method
    Range0-270, 000 cells/mL
    Detection limit300 cells/mL
    Resolution1 cells/mL
    LinearityR2>0.99
    temperature range0~ 50°C
    Protection levelIp68
    Sensor interfaceSupport RS-485, MODBUS protocol
    InstallationInput type,
    Power informationDC 5~12V, current <50mA
    sizeΦ45*175.8mm
    Probe cable length10 meters (default), can be customized
    Housing materialSS316
    Self-cleaning systemHave

    Calibration instructions


    1,Calibration of blue-green algae sensors: The blue-green algae sensor software (see the modbus manual) supports 2-point calibration. The more common environmental research dye, rhodamine B, can be used in sensor calibration.

    2,Preparation

    • First take 0.1g of rhodamine B solution into 1000mL reagent bottle A, then add DI water or distilled water to 1000mL and shake well.
    • Take 1mL of the above solution into 1000mL reagent bottle B, and then add DI water or distilled water to 1000mL and shake well. The solution concentration of reagent bottle B is 100 ppb.
    • The prepared solution should be used within 24 hours.

    3,Use

    Rhodamine B shows that the fluorescence intensity is inversely proportional to temperature. Use 100 ppb rhodamine B standard solution. To properly set the sensor to ensure the sensitivity of algae blue-green algae at 20 ° C, enter the calibration value according to the temperature standard corresponding to the table below. (The table below shows algae blue-green algae as a function of temperature approximately equal to 100 ppb rhodamine B)


    Temp, cells/ml
    2654600
    2752471
    2851376
    2949670
    3047641
    3145276
    3243258
    3340711
    3438905
    3537298
    3634875
    3733370

    Note: The calibration using rhodamine B standard solution is only an approximate value. To ensure accurate readings, the fluorescence readings obtained on site must be linked to the results obtained from the extraction analysis of the above samples. Yushan used Rhodamine B (Item # 70301027) from Keystone.

    Warning: Rhodamine B is listed as a substance that may cause carcinogenesis / induction of organism mutations. Gloves must be worn during operation.

    Maintenance methods and common problems Maintenance schedule and method

    I. Maintenance schedule

    Online blue-green algae sensor with automatic cleaning brush can be automatically cleaned without frequent cleaning.


    Maintenance taskRecommended maintenance frequency
    Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

    2. Maintenance method Sensor maintenance

    • External surface of the sensor: Clean the external surface of the sensor with tap water. If debris remains, wipe it with a moist soft cloth. For some stubborn dirt, you can add some household washing solution to the tap water to clean it.
    • Check the cable of the sensor: the cable should not be tightened during normal work, otherwise the internal wires of the cable will be easily broken and the sensor will not work properly.

    3) Check whether the measurement window of the sensor is dirty and whether the cleaning brush is normal.

    • Check the sensor's cleaning brush for damage.
    • 18 months of continuous use, need to return to the factory to replace the dynamic sealing device.

    Frequently Asked Questions


    ErrorPossible reasonsolution

    The operation interface cannot be connected or the measurement result is not

    displayed.

    Controller and cable

    connection error

    Reconnect controller and

    cable


    Cable failure

    Please contact us

    The measured value is too high, too low or the value is

    continuously unstable

    The sensor window is

    attached by a foreign object

    Cleaning the sensor window

    surface

    Damaged sensor spongeReplace the sensor sponge

    Cable Definition

    Power information

    The power supply must be DC 5-12V +/-5%, current <50mA

    Cable information

    4 wire AWG-24 or AWG-26 shielding wire. OD=5mm


    1, red line - power supply (VCC)

    2, white line - 485 data _B (485_B) 3, green line --- 485 data _A (485_A) 4, black line --- ground (GND)

    5, bare line shielding layer

    About Us

    Xi'an Desun Uniwill Electronic Technology Co., Ltd (Hereinafter referred to as Disen Sensing Company) is located in Xi'an High-tech Development Zone. It is a high-tech company integrating production, R&D, sales and engineering services. Relying on Xi'an's rich high-tech resources, we have carried out technical cooperation with many universities and scientific research institutions, constantly breaking through technical barriers, improving product performance, and using leading technology to provide high-quality products for the water quality monitoring industry.

    We launched a wireless water quality monitoring solution based on the current rapid development of the Internet of Things technology, combining smart terminals and traditional display units through wireless transmission to achieve real-time dynamic water quality monitoring functions such as data cloud display, remote cloud control, and upper and lower limit alarms.

    Quality DS206 Blue Green Algae Probe MODBUS Protocol Water Quality Monitoring Sensor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Desun Uniwill Electronic Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)