    4 20mA Output Dissolved Oxygen Sensor For Ponds 20mg/L Fluorescence Method

    Ask Lasest Price
    Brand Name : Desun Uniwill
    Model Number : DS-380
    Price : $260.00 - $360.00
    Payment Terms : L/C, D/A, D/P, T/T
    Supply Ability : 0~1000 pcs
    Delivery Time : 7~ 15 working days
    • Product Details
    • Company Profile

    4 20mA Output Dissolved Oxygen Sensor For Ponds 20mg/L Fluorescence Method

    4-20mA Output sensor, 0-20mg/L Fluorescence Method Dissolved Oxygen Probe power supply dc


    Dissolved Oxygen Sensor Features:


    • 0-20mg/L or 0-200% saturation
    • 0~50 °C; IP68 protection level
    • No film, no electrolyte, no polarization
    • No need to consume oxygen, no flow rate
    • Built-in temperature sensor, automatic temperature compensation
    • Free from chemical interferences such as sulfides
    • Small annual drift, fast response, and more accurate measurement
    • Free of maintenance, longer application cycle and lower cost of use
    • Fluor cap replacement is simple
    • Support RS-485, MODBUS protocol

    Technical Parameters


    ItemParameters
    ModelDS380
    PrincipleFluorescence analysis method
    Measuring range0~20mg/L or 0-200% saturation
    Response time3 sec
    Accuracy1%
    Protection levelIP68
    InstallationSubmersible
    Temperature sensorNTC
    Temperature range0~50°C
    Temperature accuracy±0.2°C
    OutputSupport RS-485, MODBUS protocol
    Power supplyDC 6~12V, current <50mA
    SizeΦ26*155 mm
    Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
    Fluorescent cap life1 year
    Maximum working pressure6bar
    product materialPOM/SS316/Titanium alloy
    Calibration methodOne or Two-point calibration
    Power consumption< 0.5 W

    Maintenance schedule and method


    Maintenance tasksRecommended maintenance frequency
    Cleaning sensorClean every 30 days
    Check sensor and fluorescent cap for damage

    Check every 30 days


    Replace the fluorescent capChange once a year

    Calibrate the sensor

    (if required by the competent authority)

    According to the maintenance schedule required by

    the competent authority