    PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

    Ask Lasest Price
    Brand Name : Desun Uniwill
    Model Number : DS-380
    Price : $280.00 - $360.00/ Piece
    Payment Terms : L/C, D/A, D/P, T/T
    Supply Ability : 0~1000 pcs
    Delivery Time : 7~ 15 working days
    Certification : CE
    • Product Details
    • Company Profile

    PPM Electrode Optical Dissolved Oxygen Sensor , 12V Optical Do Probe Temperature

    PPM Dissolved Oxygen Analyzer Electrode Dissolved Oxygen Sensor Do Sensor Probe Temperature


    Technical Parameters


    ItemParameters
    ModelDS380
    PrincipleFluorescence analysis method
    Measuring range0~20mg/L or 0-200% saturation
    Response time3 sec
    Accuracy1%
    Protection levelIP68
    InstallationSubmersible
    Temperature sensorNTC
    Temperature range0~50°C
    Temperature accuracy±0.2°C
    OutputSupport RS-485, MODBUS protocol
    Power supplyDC 6~12V, current <50mA
    SizeΦ26*155 mm
    Probe cable lengthDefault 5 m, customized 10m, 15 m and 30 m cable
    Fluorescent cap life1 year
    Maximum working pressure6bar
    product materialPOM/SS316/Titanium alloy
    Calibration methodOne or Two-point calibration
    Power consumption< 0.5 W

    Maintenance schedule


    Unlike the electrochemically-dissolved oxygen probe technology, the fluori-dissolved oxygen probe does not consume oxygen and does not require frequent cleaning (except when applied to viscous liquids).


    Maintenance tasksRecommended maintenance frequency
    Cleaning sensorClean every 30 days
    Check sensor and fluorescent cap for damage

    Check every 30 days


    Replace the fluorescent capChange once a year

    Calibrate the sensor

    (if required by the competent authority)

    According to the maintenance schedule required by

    the competent authority


    Note:


    The maintenance frequency in the above table is only a recommendation. Please maintain the sensor according to the actual usage of the sensor. However, the replacement of the fluorescent cap is recommended to be replaced once a year.